Descrizione

Highly accurate signal level generation in conjunction with a signal generator
Key facts
  • Measurement range: -67 dBm to +20 dBm
  • Frequency range: 9 kHz to 6 GHz
  • N connector
  • Integrated one-box solution for classic power splitter/power sensor combination
  • Special directional power sensor with integrated power splitter
  • For applications requiring a precisely known level to be fed in (e.g. calibration of measuring receivers)
  • Improvement of the absolute level accuracy of signal generators

Brief description The R&S®NRP-Z28/R&S®NRP-Z98 level control sensors were developed especially to feed power to the DUT and monitor the power at the same time.
Specifications
Level control sensors
 
Frequency range Power measurement range, maximum input power Impedance matching (SWR) Rise time, video BW Uncertainty for power measurements at +20 °C to +25 °C (1) absolute (in dB) (2) relative (in dB)
R&S®NRP-Z28, N connector
10 MHz to 18 GHz 200 pW to 100 mW (–67 dBm to +20 dBm) max. 700 mW (AVG)/ 4 W (PK, 10 ?s) 10 MHz to 2.4 GHz: <1.11>2.4 GHz to 4.0 GHz: <1.15>4.0 GHz to 8.0 GHz: <1.22>8.0 GHz to 18.0 GHz: <1.30 <8 µs,>50 kHz (1) 0.047 to 0.130 (2) 0.022 to 0.110
R&S®NRP-Z98, N connector
9 kHz to 6 GHz 200 pW to 100 mW (–67 dBm to +20 dBm) max. 700 mW (AVG)/ 4 W (PK, 10 ?s) 9 kHz to 2.4 GHz: <1.11>2.4 GHz to 4.0 GHz: <1.15>4.0 GHz to 6.0 GHz: <1.22 - (1) 0.047 to 0.083 (2) 0.022 to 0.066
''